FP-08450 Control Panel |
FP-08451 Control Panel |
FP-08850 Delayed Discharge |
FP-08860 Shutdown Module |
FP-08800 Test Simulator |
FP-08825 Thermal Fuse VSS |
|
|
|
|
|
|
Control Panel • Manual or Auto operation ▪ Twin power supply ▪ 2 Detection circuits – works with Thermal ROR, smoke detectors, or LHD ▪ All circuits monitored ▪ Options for delayed or 2nd shot and Shutdown relay ▪ 12-24vDC ▪ Compliant to NSCV. |
Control Panel. Features ▪ Manual or Auto operation ▪ Twin power supply available ▪ 2 Detection circuits – works with Thermal ROR, smoke detectors, or LHD ▪ All circuits monitored ▪ Options for delayed or 2nd shot and Shutdown relay ▪ 12-24vDC. |
Delay Discharge Module allows for the addition of FirePro Generators above the limit of 4 in the standard panel. Also provides for delayed discharge of units should longer agent discharge time is required ▪ All circuits monitored. |
Shutdown Module – connects via the siren circuit, and will allow for selectible delays for the shutdown of devices. It Provides a volt Free Contact (NO or NC) which can be used with appropriately rated relays. |
This test unit is used to check wiring connections. Used in commissioning and testing of the systems. Each system has different requirements for this device – check manual for correct selection. |
Thermal Fuse – connects to Model 08451 FIP, provides a system discharged advice, as required by AS5062. |
|
|
|
|
|
|
FP-08879 Voltage Sensitive Relay |
FP-08945 Anti-Tamper – IP67 |
FP-08458 2/4 Zone Detection Panel |
FP-08872-3 12/24v NiMH Power |
FP-08944 Siren Consolidation |
FP-14020 Dual Power Cable |
|
|
|
|
|
|
Digital Voltage Sensitive Relay provides a plug-in solution for DC power supply. Monitors and automatically isolates the incoming power supply when the power drops below an operating voltage. This avoids deep discharge of batteries |
Anti-Tamper Enclosure – IP67 suits FP-08450/1 Control Panel ▪ Waterproof ▪ Hinged lid enclosure with gasket ▪ Made from ABS plastic ▪ Anti-Tamper Seal can be fitted ▪ Clear polycarbonate cover ▪ Dimensions: 135 x 185 x 100 mm. |
2/4 Zone Detection System Control Panel.Features ▪ Twin power supply inputs available ▪ 2/4 Detection circuits – works with Thermal ROR, smoke detectors, or LHD ▪ All circuits monitored ▪ Compliant to NSCV. |
12/24v NiMH Battery a plug-in, supplementary power supply to be installed with the FP-08450/1 Fire Control Panel. The Module provides continuous power to the control panel, as per AS5062, in the event the main power supply fails. |
Siren Consolidation Module used with FP-08450/1 Control Panels to monitor and operate a singular siren circuit. This module is for use in installations where multiple control panels have been installed, but individual sirens per panel are not required. |
Dual Power input Cable used where the installation has 2 separated power supplies available – e.g. vehicles with dual battery systems. This satisfies the AS requirements for backup battery, saves installing additional battery module. |
|
|
|
|
|
|